30

Save These Instructions

Oakleaf Woodburning Stove

Dry Seasoned Wood Only!

3-90-798_R9

3. firebox
• frequency:
As necessary / Yearly
• By: User
Cleaning the firebox and internal heat exchange

surfaces is recommended to maintain thermal

efficiency. Depending on the quality and quantity of

fuel being used, you may want to perform this cleaning

monthly.
Be sure to clean these areas thoroughly at the end of

the heating season.
Brush and vacuum all internal surfaces at the end of

the heating season. Ashes will draw moisture and may

promote rust formation.

5. Chimney Connector
• frequency:
As necessary / Yearly
• By: Qualified Service Technician / User
At the end of the burn season, brush and clean all

sections of chimney connector pipe. Some owners

remove the chimney connector for the off season.

Any ashes left in the connector pipe will actually draw

moisture which promotes rust. This is why it is very

important to clean all ashes at the end of the heating

season.
When cleaning the chimney connector above the

appliance, keep the bypass damper in the open

position. This will keep any loosened material from

falling into the Firedome combustion chamber.

6. Chimney
• frequency:
As necessary / Yearly
• By: Qualified Service Technician / Chimney Sweep
The entire chimney should be professionally cleaned

at least once yearly. It is best to have this done at

the end of the heating season to be sure all ash is

removed. You'll also want to inspect the condition of

the chimney prior to using the appliance, to be sure

there are no bird or animal nests.

4. Blower- If installed
• frequency:
As necessary / Yearly
• By: User
The fan on the blower will collect debris over time. Any

accumulation must be removed to maintain proper

operation.
To clean blower;
• Disconnect power cord before servicing.
• Remove the two bolts that hold the blower in place.
• Use a vacuum and/or brush to remove all dust and

pet hair from the blower wheel.

• Reinstall the blower and tighten the two bolts

securely.