Warning, Caution, Installation – Honeywell F111 Series 1 User Manual

Page 4: Choose location, When installing this product, Unpack the air cleaner

Advertising
background image

F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER

68-0198-2 Revised 5-09

4

WARNING

TO REDUCE THE RISK OF FIRE,ELECTRICAL
SHOCK, OR INJURY TO PERSONS,OBSERVE THE
FOLLOWING:

1.

Installation Work And Electrical Wiring Must Be Done
By Qualified Person(s) In Accordance With All Applica-
ble Codes And Standard, Including Fire Rated Con-
structions.

2.

When Cutting Or Drilling Into The Wall Or Ceiling, Do
Not Damage Electrical Wiring And Other Hidden Utili-
ties.

3.

Never Place A Switch Where It Can Be Reached From
A Tub Or Shower.

4.

Use This Unit Only In The Manner Intended By The
Manufacturer. If You have Questions, Contact The Man-
ufacturer.

5.

Before Servicing Or Cleaning Unit, Switch Power Off At
Service Panel And Lock Service Panel To Prevent
Power From Being Switched on Accidentally.

6.

If This Unit Is To Be Installed Over A Tub Or Shower, It
Must Be Marked As appropriate For The Application
and be connected to a GFCI (Ground Fault Circuit Inter-
rupter) - protected branch circuit.

Choose Location

Choosing the correct location for the air cleaner affects the
overall performance of the unit. The bidirectional airflow
pattern must flow into the longest reaches of the zone being
cleaned. See Fig. 2

NOTE: The F111 Has Not Been Investigated
For Use In Fire Resistance Rated
Construction.

Fig. 2. Correct positioning of the air cleaner

for optimum cleaning.

The air cleaner is designed to be suspended centrally in a
space and mounted into or on a ceiling. The cleaning footprint
of the air cleaner is rectangular with air patterns that move
clean air to the corners of the area while drawing contaminated
air up from the center of the area. See Fig. 2.

When multiple air cleaners are installed, the allotted areas to
be cleaned should be equal. The air throw in one direction is
approximately 55 ft (17m). Air velocity at 90 ft per minute
(27m per minute) is considered end of throw.

IMPORTANT

Never hang the air cleaner higher than 16 ft (5m)
above the floor.

INSTALLATION

WARNING

Explosion Hazard Possible.
Can cause personal injury or equipment damage.
Do not install or use the F111 (series 11000) air
cleaner where there is any danger of gas, vapor or
dust explosion.

IMPORTANT

This air cleaner has not been investigated for use in
the ceilings of fire-resistant assemblies.

CAUTION

Electrical Hazard.
Can cause personal injury or equipment damage.
Turn off power before installing or servicing the air
cleaner.

IMPORTANT

Stand on a stable platform when working with the air
cleaner.

When Installing this Product…

1.

Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous condi-
tion.

2.

Check the ratings given in the instructions and on the
product to make sure the product is suitable for your
application.

3.

Installer must be a trained, experienced service techni-
cian.

4.

After installation is complete, check out product opera-
tion as provided in these instructions.

Unpack the Air Cleaner

Check that all components are included. The unit consists of:

cabinet and grille/door assembly,

media modules,

literature.

35001 to 51000

(1050 to 1530)

91 to 120

3

51001 to 65000

(1530 to 1950)

121 to 180

4

65001 to 80000

(1950 to 2400)

181 to 240

5

80001 to 95000

(2400 to 2850)

241 to 300

6

Space Volume

(L x W x H) in Cubic

Feet (Cubic Meter)

Number of

Persons Present

Minimum

Number of Air

Cleaners

F111

(SERIES

11000)

CLEANING FOOTPRINT

CEILING

FLOOR

CORRECT

2

1

INCORRECT

M12652A

Advertising
This manual is related to the following products: