D. specifications, Specifications, Appendix d – Fluke Ti20 User Manual

Page 67

Advertising
background image

D-1

Appendix D

Specifications

Thermal
Temperature Range............................................ -10 to 350

°

C (14 to 662

°

F)

Detector Type ..................................................... 80 x 60 thermal element focal plane array (FPA)
Accuracy .............................................................

±

2

°

C or 2 % (whichever is greater)

Repeatability .......................................................

±

1 % or

±

1

°

C (

±

2

°

F) whichever is greater

NETD (Thermal Sensitivity) ................................ 200 mK
Temperature Indication ....................................... 0.1

°

C or 0.2

°

F

Optical
Field of View (FOV)............................................. Rectangular. 20

°

Horizontal x 15

°

Vertical

Minimum Diameter.............................................. 8.1 mm (0.32 in) at 61 cm (24 in)
Optical Resolution (D:S) ..................................... 75:1 or better
Spectral Range ................................................... 7.5 to 14 microns
Target Sighting.................................................... Single Laser (IEC 825/93 Class II, FDA LFR 1040.10 Class II
Instantaneous Field of View................................ 4.4 mrad
Controls
Focus .................................................................. 61 cm (24 in) to infinity
Temperature Scale .............................................

°

C or

°

F selectable

Palettes............................................................... Original, Gray, Rainbow (default), Ironbow, Gray Reverse
Measurement Modes .......................................... Automatic or Manual
LCD Backlight ..................................................... Bright/Dim selectable
Operational
Adjustable Emissivity .......................................... .10 to 1.00 by 0.01
Liquid Crystal Display ......................................... 70.5 mm (2.78 in) x 53.5 mm (2.1 in)
Reflected Background Temperature ................... -50 to 905

°

C (-58 to 1661

°

F)

Ambient Operating Temperature ........................ 0 to 50

°

C (32 to 122

°

F)

Relative Humidity................................................ 10 to 90 % noncondensing
Storage Temperature.......................................... -25 to 70

°

C (-13 to 158

°

F) without batteries

Storage Capacity ................................................ 50 images
Electrical
Power.................................................................. Rechargeable battery pack (included)
Battery Life.......................................................... Minimum 3 hours continuous use
Battery Charge Time........................................... 2 hours in the Imager, 1 hour in the external charger (or until the green

LED turns on)

Data Transfer ...................................................... USB interface, transfer time 25 sec for 50 images
Storage Device ................................................... Flash Memory