DEAN MILLIVOLT GAS FRYERS (NON-CE)

CHAPTER 3: INSTALLATION INSTRUCTIONS

3-10

3.7 Gas Conversion Procedures


See gas valve illustration below and gas valve, burner and orifice location on page 3-11 when
performing the following conversions.

When converting from natural gas to propane (or vice-versa), the following procedures apply:

♦ Burner orifices and pilot orifice MUST be replaced (See page 3-9 for required component

part numbers).

♦ Adjust orifice gas pressure by turning the gas-valve adjustment screw (See page 3-9 for

various gas types and pressures).

♦ After adjustment, replace the adjustment-screw cover.
♦ Affix the new label included with the conversion kit next to the exiting rating plate stating

that the gas type has been converted. Remove any references to the previously used gas
from the existing rating plate.


Conversion from one gas family to another (i.e. changing from natural gas to propane) requires
special components. Obtain the necessary components using the tables on page 3-9.


Conversions can only be executed by qualified, factory-authorized personnel.

Pressure flow adjustment
(remove cover screw to access)

ON/PILOT/OFF

Gas-Cock Knob

Pilot gas supply connection

Regulator Vent

Pilot pressure adjustment

(remove cover screw to access)

Pressure Tap


Typical gas valve (Millivolt- Non-CE).

Advertising