7 gas conversion: procedures (cont.), 8 gas conversion components – Frymaster SM60 User Manual

Page 27

Advertising
background image

DEAN MILLIVOLT GAS FRYERS (NON-CE)

CHAPTER 3: INSTALLATION INSTRUCTIONS

3-11

3.7 Gas Conversion: Procedures (cont.)


Vessel Assembly

Gas Valve

Manifold Support Bracket

Gas Burner

See Detail A

Pressure

Test

Spigot

Orifice

Temperature

Control

Gas

Manifold

Assembly

1/2—3/4 Reducer

Bushing

Burner

Gas Manifold

Burner/Orifice Location

Detail A

Orifice

1.30-inch [33-mm]

1.63-inch [41-mm]




3.8 Gas Conversion Components


Use the following components to convert from natural gas to propane and vice-versa. See Section
3.6 for orifice quantities required for conversion.

Natural Gas to Propane Kit, 826-1817

Propane To Natural Gas Kit, 826-2017

Bushing, NPT Flush, SR 42 Series only

Bushing, NPT Flush, SR 42 Series only

Pilot orifice (16LP)

Pilot orifice (26N)

Burner orifice*
(See Table on Page 3-9)

Burner orifice*
(See Table on Page 3-9)

Rating label, contact factory at time of
conversion.

Rating label, contact factory at time of
conversion.

* Burner orifices listed on page 3-9 are for fryers operating at altitudes of 2000 feet or less. For

altitudes greater than 2000 feet, contact the factory for the correct orifice size.

Typical gas valve, burner and orifice locations (SM50 shown above).

Advertising