Fluke DSP-2000 User Manual

Page 51

Advertising
background image

Autotest

Autotest on Twisted Pair Cable

3

3-3

Note

The REMOTE tests will run only if the remote is a smart remote or a
DSP-100 with the SMART REMOTE mode selected.

1.

If you are using a DSP-100 main unit as the remote, turn the remote unit’s
rotary switch to SMART REMOTE. If you are using a smart remote unit, turn
its rotary switch to ON.

2.

Use a 2m patch cable of the correct impedance to connect the remote to the far
end of the cable link.

3.

On Model DSP-100, remove any cable connected to the test tool’s BNC
connector.

4.

Turn the rotary switch on the main unit to AUTOTEST.

5.

Verify that the settings displayed are correct. You can change these settings in
the SETUP mode.

6.

Use a 2m patch cable of the correct impedance to connect the test tool to the
near end of the cable link. On Model DSP-2000, connect to the CABLE TEST
jack.

7.

Press

T to start the Autotest.

Notes

Pressing

T when the previous Autotest was not saved causes the

test tool to display a warning message. In this case, you can either
save the results of the previous test by pressing

S or delete the

results and start a new Autotest by pressing

T.

If a remote is not connected, the test tool displays the message

SCANNING FOR REMOTE and does not run the Autotest until a
remote is connected.

If the calibration message appears, refer to “Calibrating the Test
Tool” in Chapter 6 for complete calibration instructions.

Advertising
This manual is related to the following products: