Cable types tested, Test standards, Time for autotest – Fluke DSP-2000 User Manual

Page 146: Characteristic impedance

Advertising
background image

DSP-100/2000

Users Manual

8-8

Cable Types Tested

Unshielded twisted pair LAN cables of all categories (UTP category 3, category 4,
and category 5).

Foil-screened twisted pair cables (ScTP): category 3, category 4, and category 5.

Shielded twisted pair cables (STP) (IBM Type 1, 6, and 9; adapter required).

Coaxial cables: Thicknet (10Base5; adapter required), Thinnet (10Base2), RG-58,
RG-58 foam, RG-59, RG-59 foam, RG-8, RG-8A/U, and RG-62.

Test Standards

TIA category 3, 4, and 5, basic link or channel, and TIA TP-PMD.

IEEE 802.3 10Base5, 10Base2, and 10BaseT.

IEEE 802.5 Token Ring 4 Mb/s or 16 Mb/s.

IEEE 100BaseTX, 100BaseT4, IEEE 802.12 (100BaseVG).

ISO Class A, B, C, and D.

ANSI TP-PMD

Time for Autotest

Full 2-way Autotest of category 5 UTP cable in approximately 20 seconds.

Characteristic Impedance

Table 8-3 shows the specifications for the characteristic impedance test.

Table 8-3. Characteristic Impedance Test Specifications

Twisted Pair cable

Coax

Range

70 - 180

35 - 100

Accuracy

± (5

+ 5%

Nominal - Measured

)

± (5

+ 5%

Nominal - Measured

)

Anomaly Threshold

15% Reflection

10% Reflection

Resolution

1

1

Advertising
This manual is related to the following products: