Rl@remote (model dsp-2000) – Fluke DSP-2000 User Manual

Page 66

Advertising
background image

DSP-100/2000

Users Manual

3-18

Pressing

@ View Plot produces the RL plot screen. Figure 3-6 shows an

example of the screen and Table 3-9 describes the items on the screen.

5

2

1

6

4

3

gc13c.eps

Figure 3-6. The RL Plot Screen

Table 3-9. Items on the RL Plot Screen

Item

Description

1

The cable pair relevant to the plot.

2

Frequency range in MHz of the RL test.

3

Margin is the difference between the limit and measured values plotted at the cursor’s
position. Use

L

R

to move the cursor left or right. If you move the cursor beyond the highest

test frequency specified by the selected test standard, the readout shows the RL value at
the cursor’s position.

4

The limits for RL, as defined by the selected test standard.

5

Decibels of RL for the cable pair.

6

The measured RL for the cable pair.

RL@REMOTE (Model DSP-2000)

The RL@REMOTE test is identical to the RL test, except that the RL values are
measured from the remote end of the cable.

Advertising
This manual is related to the following products: