Scanning function, When to use a remote unit – Fluke DSP-2000 User Manual

Page 78

Advertising
background image

DSP-100/2000

Users Manual

4-2

Scanning Function

The Single Test versions of the wire map, resistance, TDR, and TDX analyzer
tests include a scanning function, which you can activate by pressing the

#Scanning ON softkey. The scanning function runs the test repeatedly
and updates the display each time a test is complete. This function is useful for
finding intermittent problems on a cable.

Note

To extend battery life, connect the ac adapter/charger when using
the scanning function for more than 1 minute.

When to Use a Remote Unit

A remote unit is required only when testing twisted pair cable. Table 4-1 shows
which cable tests require a remote and which remotes support each test.

If a remote unit is detected at the start of a Single Test, the test tool runs a wire
map test before running the selected test. If the wire map test fails, the test tool
stops the test and displays the wire map. Press

$Continue Test to run

the selected test.

Note

Model DSP-2000 is compatible only with Model DSP-2000SR units.
Model DSP-100 is not compatible with Model DSP-2000SR units.