Running Individual Tests

The TDX Analyzer

4

4-7

If the test tool does not detect a remote, the following message appears:

NO REMOTE DETECTED. To run the TDX analyzer, press E. To
restart the analyzer and scan for the remote again, press

T. To return to the first

Single Test screen, press

e.

TDX Analyzer Results

When the TDX analyzer test is complete, the TDX analyzer results screen
appears. Table 4-2 describes the items on the analyzer screen.

Table 4-2. Items on the TDX Analyzer Results Screen

Item

Description

Pairs

The cable pairs relevant to the results.

Peak

The highest magnitude of crosstalk measured on the cable pair. A peak over
50 indicates a crosstalk level that exceeds the limit specified by the selected
test standard. Crosstalk levels are adjusted to compensate for cable
attenuation.

Distance

The measured distance from the main unit to the peak crosstalk value.

#

View Plot

Press to see a plot that shows where crosstalk is detected on the cable.