Tdx analyzer plot – Fluke DSP-2000 User Manual

Page 84

Advertising
background image

DSP-100/2000

Users Manual

4-8

TDX Analyzer Plot

To view a TDX analyzer plot for a set of cable pairs, use

D U to highlight the

pairs, then press

#View Plot to see the plot screen for the pairs. Figure

4-2 shows an example of a TDX analyzer plot and Table 4-3 describes the items
on the screen.

1

2

3

4

5

gc20c.eps

Figure 4-2. Example of a TDX Analyzer Plot for a Good Twisted Pair Cable Run

Table 4-3. Items on a TDX Analyzer Plot

Item

Description

1

The cable pairs relevant to the results.

2

The distance along the cable under test. The 0 at the left of the scale represents the
location of the main test tool.

3

Magnitude of crosstalk on the cable pair. A peak over 50 indicates a crosstalk level
that exceeds the limit specified by the selected test standard. Crosstalk levels are
adjusted to compensate for cable attenuation.

4

The Cursor Readout shows the distance to the crosstalk source at the cursor’s
position. Use

L

R

to move the cursor left or right.

5

Use

D

U

to change the maximum distance of the horizontal scale.