4 choosing data source(s) – Furuno GP-7000F User Manual

Page 38

Advertising
background image

32

8. Rotate the [ENTER] knob to set digit and push the [ENTER] knob. To clear a line of data,

press the [CLR FLD] soft key (one of the keys below the screen).
Setting range
Draft setup: -20 - +39.9 (ft)
Speed calibration: -50 - +50 (%)
Temp calibration: -50 - +5 (

°

F)

Acoustic speed calibration: -50 - +50 (ms)

9. Set other digits as you did in step 8.

10.Press the [SAVE] soft key (one of the keys below the screen).

11.If necessary, follow steps 5-11 to set other items.

12.Press the [MENU] key to close all open windows and erase the menu bar.

3.4

Choosing Data Source(s)

Choose the source of depth, water temperature and speed data as follows:

1. Press the [MENU] key to show the menu bar.

2. Rotate the [ENTER] knob to choose ADVANCED on the menu bar and then push the

[ENTER] knob.

3. Rotate the [ENTER] knob to choose INPUT/OUTPUT and then push the [ENTER] knob.

4. Rotate the [ENTER] knob to choose DEPTH SOURCE, TEMP SOURCE or STW SOURCE

(speed) depending on your system configuration and then push the [ENTER] knob.

5. Rotate the [ENTER] knob to choose NMEA or Sounder as appropriate and then push the

[ENTER] knob. Choose Sounder if you wish to use sounder-generated depth, water tempera-
ture or speed data. (Optional water temperature/speed sensor required to use Sounder-gen-
erated water temperature/speed data.)

6. Press

W

to close the window.

7. If applicable, repeat steps 4 thru 6 to choose other data sources.

8. Press the [MENU] key to close all open windows and erase the menu bar.

Note:The following data sentences are required to display respective data. Depth: DPT (Ver. 2.0)
or DBT (Ver. 1.5), Temperature: MTW, and STW (Speed Thru Water): VTG, RMC or RMA.

NMEA

Sounder

Advertising