Frymaster FOOTPRINT H50 User Manual

Page 10

Advertising
background image

1-5

3. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and

plug in the electrical cords.


1.3

Cleaning the Gas Valve Vent Tube

1. Set the fryer power switch and the gas valve to the OFF position.

2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened

for ease of removal.

3. Pass a piece of binding wire (.052 inch diameter) through the tube to remove any obstruction.

4. Remove the wire and blow through the tube to ensure it is clear.

5. Reinstall the tube and bend it so that the opening is pointing down.

1.4

Checking the Burner Manifold Gas Pressure

1. On non-CE fryers only, ensure that the gas valve knob is in the OFF position.

Honeywell

ON

OFF

2. Remove the pressure tap plug from the gas valve assembly.

Typical Non-CE

Valve Assembly

Typical CE Valve

Assembly

Pressure Tap Plug

3. Attach a manometer or pressure gauge to the pressure tap hole.

Advertising