1-10

1.6.5 Replacing an Ignitor Assembly

DANGER

Drain the frypot or remove the handle from the drain valve before proceeding further.


1. Disconnect the fryer from the electrical supply.

2. Disconnect the flame sensor wire by carefully pulling its push-on terminal from the terminal

strip on the ignitor. Disconnect the gas enrichment tube at the ignitor-end compression fitting.
Disconnect the ignition cable from the ignitor by grasping its boot and gently pulling toward
you.

3. Remove the sheet metal screws securing the ignitor to the mounting plate and pull the ignitor

from the fryer.

4. Reverse the procedure to install the replacement ignitor.

1.6.6 Replacing or Cleaning a Combustion Air Blower

1. Disconnect the blower wiring harness, remove the blower assembly mounting nuts, and remove

the blower assembly from the fryer. If cleaning the motor, continue with Step 2; otherwise,
install the replacement blower, reconnect the wiring harness, and then go to Step 6.

Wiring connection

Blower assembly

mounting nuts

Flame Sensor Wire

Gas Enrichment Tube


Ignition Cable

Advertising