3-4

ITEM PART

#

COMPONENT

1

106-6708

Interface Board, SMT, Gas, non-Basket Lift, FV (U.S., Canada, Mexico)

2

826-2264

Interface Board, SMT, Gas, with Basket Lift, FV (U.S., Canada, Mexico)

3

106-6707

Interface Board, SMT, Gas, non-Basket Lift, FV (Export)

4

106-6711

Interface Board, SMT, Gas, non-Basket Lift, DV (FAST)

5

807-3366

Ignition Module, Dual-spark, Full-vat (U.S., Canada, HK, Mexico)

*

807-3365

Ignition Module, Single-spark, Dual-vat (U.S., Canada, H.K., Mexico)

6 807-1006

Ignition Module, CE/non-CE Export (except Australia, Canada, H.K., Mexico)

* 807-2971

Ignition

Module

(Australia)

7

806-6085

Wire, Ignitor

* 807-3483

Cable,

Ignition

8

807-1878

Cable, 19" Ignition (used with 807-1006)

9 807-3484

Connector,

Rajah

10 807-0833

Relay,

Latch/Valve

11

807-3969

Relay, 5A (24VDC)

12

807-0834

Relay, Basket Lift, 15A, 12V

13

810-1164

Block, 1 Piece Screwless Terminal

14

816-0217

Paper, CE Single Terminal, Black, Insulating

* Not illustrated.

NOTE 1: U.S., Canadian, Hong Kong, and Mexican units use two different modules depending upon the configuration of the frypot.
Dual-vat units use two 807-3365 Single-Spark Ignition Modules. Full-vat units use one 807-3366 Dual-Spark Ignition Module. Also,
in full-vat units, only one latch relay (Item 10) is used, located in the lower right socket.

NOTE 2: Basket Lift Relays (Item 12) are present only on units equipped with basket lifts.

3.4

Single H50/55 High-Limit Thermostat and Temperature Probe

1

2

3

ITEM PART

#

COMPONENT

1 826-1177

High Limit Thermostat - 425

°F/218°C

2

806-4206

Temperature Probe

*

106-8457SP

Temperature Probe, FAST

*

806-5046

Cable, FAST Probe

3 210-0681

Probe

Guard

* Not illustrated.