Frymaster FOOTPRINT H50 User Manual

Page 89

Advertising
background image

2-33

ITEM PART

#

COMPONENT

1

Ignitor

(includes gasket 816-0059, which may be ordered separately)

826-0981

Natural Gas (G20, G25)

826-0982

Propane (G30, G31)

826-1002

Manufactured

Gas

2

826-1371

Screw, #8 X 1/2-inch Hex Head (pkg. of 25)

3

Blower Assembly, Combustion Air (includes harness and Items 4, and 5)

106-2996SP

100V 50/60 Hz (Left)

106-2999SP

100V 50/60 Hz (Right)

106-2994SP

115V 50/60 Hz. (Left)

106-2997SP

115V 50/60 Hz (Right)

106-2995SP

208-240V 50/60 Hz (Left)

106-2998SP

208-240V 50/60 Hz (Right)

106-3000SP

230V 50/60 Hz CE (Left)

106-3001SP

230V 50/60 Hz CE (Right)

4

816-0554

Cover, Blower Motor (component of all blowers listed above)

5

809-0938

Screw, 10-32 X 5/8-inch Philips Truss Head (secures Item 4 to Item 3)

*

806-8806SP

Harness Assembly, Blower Motor (component of all blowers listed above)

6

Orifice,

Burner

812-1137

1.95 mm Propane/Butane (G30, G31) (0-4999 Ft, 0-1524 M) (CE)

810-1221

2.00 mm Propane/Butane (0-4999 Ft, 0-1524 M) (Japan only)

810-0386

2.10 mm Propane/Butane (0-4999 Ft, 0-1524 M)

810-0413

2.16 mm Propane/Butane (G30, G31) (5000-6999 Ft, 1525-2133 M)

812-1028

2.20 mm Propane/Butane (G30, G31) (7000-10,999 Ft, 2134-3352 M)

812-1134

3.10 mm Natural Gas (G20, G25) (0-4999 Ft, 0-1524 M) (Japan only)

810-0403

3.40 mm Natural Gas (G20, G25) (0-4999 Ft, 0-1524 M)

810-0437

3.60 mm Natural Gas (G20, G25) (5000-6999 Ft, 1525-2133 M)

812-1144

3.65 mm Natural Gas (G20, G25) (7000-8999 Ft, 2134-2743 M)

812-1145

3.70 mm Natural Gas (G20, G25) (9000-10,999 Ft, 2744-3352 M)

810-0642

5.95 mm Manufactured Gas (0-4999 Ft, 0-1524 M)

CE Conversion Kits

*

826-1196

Natural Gas (G20, G25) to Propane/Butane (G30, G31), Full-vat/Dual-vat

*

826-1197

Propane/Butane (G30, G31) to Natural Gas (G20, G25), Full-vat/Dual-vat

Non-CE Conversion Kits

*

826-1145

Natural Gas (G20, G25) to Propane/Butane (G30, G31), Full-vat

*

826-1146

Propane/Butane (G30, G31) to Natural Gas (G20, G25), Full-vat

*

826-1147

Natural Gas (G20, G25) to Propane/Butane (G30, G31), Dual-vat

*

826-1148

Propane/Butane (G30, G31) to Natural Gas (G20, G25), Dual-vat

* 807-2263

Switch, Air Pressure (use 807-2262 in units with 100VAC power supply)

* Not illustrated.

Advertising