Operation programming, Nicd mode – Fusion TYPHOON L50B PRO User Manual

Page 8

Advertising
background image

6

NiCd CHARGE

C=3.0A

BATT TYPE

NiCd CHARGE

C=3.0A

START

BATTERY CHECK

WAIT PLEASE....

CHG 0:00 00000

NC+3.00A 5.200V

INC

DEC

ENTER

INC

DEC

NiCd delta-peak-

volt = 0mV/cell

NiCd delta-peak-

volt = 0mV/cell

ENTER

INC

DEC

Setting Charge Current

Adjust the desired charge current, which ranges from 0.1A to

6.0A with the INC & DEC buttons. Press the ENTER button to

confirm the setting.

Setting Delta Peak Sensitivity

Set the Delta Peak Sensitivity from 5mV to 25mV per cell with

the INC & DEC buttons and press the ENTER button to confirm

the setting.

NiCd CHARGE

C=3.0A

NiCd delta-peak-

volt = 0mV/cell

NiCd Mode

• When the charger is connected to the power source the charger will show the

battery mode that was last used.

• If the battery TYPE button is briefly pressed, the present battery type (NiCd, NiMH,

Lithium, or Pb ) will flash. While the existing battery type is flashing, every time

the battery TYPE button is pressed, the following modes are shown in order:

• If the other buttons are pressed, or nothing is pressed, the present battery type

stops flashing.

• If the Battery TYPE button is pressed and briefly held, the recent & previous data

will be shown until the Battery TYPE button is pressed.

• If the ENTER button is briefly pressed, a parameter which can be adjusted starts

to flash and if the ENTER button is pressed again, the next parameter starts to

flash. If nothing is pressed for 3 seconds, the parameter stops flashing.

• Once the ENTER button is pressed and briefly held, the charger starts to charge

according to the selected parameters.

NiCd CHARGE

C=3.0A

BATT TYPE

NiMH CHARGE

C=3.0A

BATT TYPE

LiIo CHARGE 3.0A

C=3000mAh 10.8Vp

BATT TYPE

Pb CHARGE

C=3.0A 12V Pack

BATT TYPE

OpErAtion

progrAmming