H per kw, Ce standard – Frymaster BK1814 User Manual

Page 20

Advertising
background image

Frymaster BK1814 Series Gas Fryers

Chapter 3: Installation

3-6

The 1814 Series gas fryer has received the CE mark for the countries and gas categories indicated in the table
below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU and category 3P/B, which is
23kW.



COUNTRIES CATEGORIES

GAS

PRESSURE

(MBAR)

AUSTRIA (AT)

II2H3B/P

G20 20

G30, G31

50

BELGIUM (BE)

I2E(R)B G20,

G25

20,

25

I3+ G30,

G31 28-30,

37

DENMARK (DK)

II2H3B/P

G20 20

G30, G31

30

FRANCE (FR)

II2Esi3+

G20, G25

20, 25

G30, G31

28-30, 37

II2Esi3P

G20, G25

20, 25

G31 50

FINLAND (FI)

II2H3B/P

G20 20

G30, G31

30

GERMANY (DE)

II2ELL3B/P

G20, G25

20

G30, G31

50

I3P G31

50

GREECE (GR)

II2H3+

G20 20

G30, G31

28-30, 37

ITALY (IT)

II2H3+

G20 20

G30, G31

28-30, 37

IRELAND (IE)

II2H3+

G20 20

G30, G31

28-30, 37

LUXEMBOURG (LU)

II2E3B/P

G20 20

G30, G31

50

NETHERLANDS (NL)

II2L3P

G25 25
G31 50

II2L3B/P

G25 25

G30, G31

30

NORWAY (NO)

I3B/P

G30, G31

30

PORTUGAL (PT)

II2H3+

G20 20

G30, G31

28-30, 37

SPAIN (ES)

II2H3+

G20 20

G30, G31

28-30, 37

II2H3P

G20 20
G31 37,

50

SWEDEN (SE)

II2H3B/P

G20 20

G30, G31

30

UNITED KINGDOM (UK)

II2H3+

G20 20

G30, G31

28-30, 37

CE Standard

Required airflow for the combustion air supply is 2m

3

/h per kW.

1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting under the front of the

fryer and to the building gas line.

NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units are
connected to the gas supply line at the rear of the unit.

When using thread compound, use very small amounts on male threads only. Use
a pipe thread compound that is not affected by the chemical action of LP gases
(Loctite™ PST56765 Sealant is one such compound). DO NOT apply compound

CE Approved Gas Categories by Country

Advertising