Frymaster BK1814 User Manual

Page 22

Advertising
background image

Frymaster BK1814 Series Gas Fryers

Chapter 3: Installation

3-8

CE GAS CONVERSION INSTRUCTIONS


1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the

CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice.


2. Between a 2

nd

family (G20 or G25) and a 3

rd

family gas (G30 Butane or G31 Propane):

a.

Change

the

orifices.

b. Adjust the manifold pressure.


3. Affix the new label included with the conversion kit next to the existing rating plate stating that

the gas type has been converted. Remove any references to the previously used gas from the
existing rating plate.


Conversions can only be executed by qualified, factory-authorized personnel
.

Pressure flow adjustment

(remove cover screw to

access)

ON/OFF

Gas-Cock Knob

Pilot gas supply

connection.

Regulator Vent

Pilot pressure adjustment

(remove cover screw to

access)

Typical non-CE gas valve for electronic-ignition equipped fryers.

Advertising