Cavity preparation, Important – Fisher & Paykel DD60D 7 User Manual

Page 9

Advertising
background image

9

7

CAVITY PREPARATION

Water Connection

Recommended COLD
(Maximum 60°C).

¾ “ BSP (GB20) to
suit flat washer.

Kosher requirements

Drains will need to be
separated to satisfy
kosher requirements.
We suggest you confirm
acceptability with your
local rabbi in respect to
kosher installations.

Water Pressure

Water softener models
Max. 1 MPa (145 psi)
Min. 0.1 MPa (14.5 psi)

Models without water softener
Max. 1 MPa (145 psi)
Min. 0.03 MPa (4.3 psi)

Important!

The power outlet must be
located in a cabinet adjacent
to the dishwasher cavity.

220-240 VAC min. 9.5 A

ø

60 mm

min. 200 mm

Moisture

protection

tape must

be applied.

Services can be

located either side

of dishwasher.

These marks indicate

formed bracket screw

locations, if securing

by drawer removal.

10 mm

BENCHTOP