Frymaster 24G Series User Manual

Page 12

Advertising
background image

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 2: IMPORTANT INFORMATION

2-4

2.5 Pre-Installation

DANGER

No structural material on the fryer should be altered or removed to accommodate

placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service

Hotline at 1-800-551-8633.


DANGER

Do not connect this appliance to the gas supply before reviewing all information in

this chapter.



A. General: Only licensed personnel (as defined in Section 1.5) should install any gas-fired

equipment.

1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for

safety and ease of future service.

2. Dean 24G Series Flatbottom gas fryers require 120 VAC (Non-CE), or 230VAC (CE), and

are equipped with a 16-3 SJT power cord.


B. Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-

certified for the following installations:

1. Commercial installation only (not for household use).

2. Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable

legs or optional 5-inch (13-cm) casters;

3. Combustible construction with a minimum clearance of 6-inch (15 cm) side and 6-inch (15

cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or optional 5-
inch (13-cm) casters.

DANGER

Local building codes prohibit a fryer with its open tank of hot oil from being installed

beside an open flame of any type, including those of broilers and ranges.

Advertising