Specifications

Function Specifications

3

37

Function Specifications

For all specifications, probe specifications must be added.

Electrical functions

Specifications are valid for signals with a fundamental between 40 and 70 Hz.
Minimum input voltage ..................................................................4 V peak-peak
Minimum input current..................................................10 A peak-peak (1 mV/A)
Input bandwidth ................................. DC to 15 kHz (unless specified otherwise)

Volts / Amps / Hertz
Readings ....................................................V rms (AC+DC), A rms (AC+DC), Hz

Voltage ranges (auto) ...........................................5.000 V to 500.0 V, 1250 V

±(1 % + 10 counts)

Current ranges (auto) ....................................... 50.00 A to 500.0 kA, 1250 kA

±(1 % + 10 counts)

Frequency range ............................................................. 10.0 Hz to 15.0 kHz

40.0 to 70.0 Hz ............................................................±(0.5 % + 2 counts)

CF Crest Factor range............................................1.0 to 10.0 ±(5 % + 1 counts)

Power
(1 and 3 Phase, 3 Conductor balanced loads)
Readings ................................................................ Watt, VA, VAR, PF, DPF, Hz

Watt, VA, VAR ranges (auto).............. 250 W to 250 MW, 625 MW, 1.56 GW

when selected: total (%r):

±(2 % + 6 counts)

when selected: fundamental (%f):

±(4 % + 4 counts)

DPF .............................................................................................. 0.00 to 1.00

0.00 to 0.25.............................................................................not specified
0.25 to 0.90....................................................................................... ± 0.04
0.90 to 1.00....................................................................................... ± 0.03

PF ..................................................................................... 0.00 to 1.00, ± 0.04
Frequency range ............................................................. 10.0 Hz to 15.0 kHz

40.0 to 70.0 Hz ............................................................±(0.5 % + 2 counts)

Harmonics
Number of harmonics ..................................................... DC..21, DC..33, DC..51

Readings / Cursor readings

V rms / I rms .............................................................fund. ±(3 % + 2 counts)

31

st

±(5 % + 3 counts), 51

st

±(15 % + 5 counts)

Watt ..........................................................................fund. ±(5 % + 10 counts)

31

st

±(10 % + 10 counts), 51

st

±(30 % + 5 counts)

Frequency of fundamental................................................................± 0.25 Hz

Advertising