Input/Output

QTY

Potential transformers (PTs)

2

3-phase standard, single phase available

120 V ac nominal
1 VA nominal burden

Current transformers (CTs, 1 or 5 A)

2

Any two phases, single phase available

1 VA nominal burden

86G dedicated contact input

1

open for trip

52G dedicated contact input

1

closed for online

Trip rated contact outputs

2

At 125 V dc with relay break characteristics:

Resistive load 0.5 A
Inductive load 0.2 A

General Purpose contact inputs

6

Customer contacts, 70 V dc supplied by ECTB

General Purpose Form C contact outputs

4

At 125 V dc with relay break characteristics:

Resistive load 0.5 A
Inductive load 0.1 A

± 10 V differential amplifier input

1

Thermal

Base controls cabinet

Continuous operation in a 0 to 40 ºC ambient environment, with 5 to
95% humidity, non-condensing

Base power conversion and auxiliary
cabinet

Continuous operation in a 0 to 40 ºC ambient environment, with 5 to
95% humidity, non-condensing

Cabinet Dimensions & Weight

Redundant control with dual PCM
redundant converter in a three-cabinet
lineup

Width 141.74 in (3600 mm)
Height 104.32 in (2650 mm)
Depth 31.5 in (800 mm)

Weight of Converter cabinet

3,600 lbs

Weight of Total Lineup (Converter,
Control, and Auxiliary cabinets)

5,600 lbs

Cabinet type, control & auxiliary
enclosures

NEMA 1 (IEC IP 20), convection cooled

Cabinet type, power conversion

NEMA 1 (IEC IP 20), forced air cooled

Power and Control Cable Access

Entrances from the top and/or bottom

Advertising