TIMBER FRAMED BUILDINGS

1.5 It will be necessary to provide additional clearance when

the flue passes through a wall containing any combustible

materials so as to prevent a fire hazard.

1.6 The hole through which the flue will pass, must have a steel

sleeve which is positioned so that an air gap of at least

25mm is maintained between the outer surface of the flue,

and any part of the sleeve.

1.7 For further guidance on the installation of gas appliances in

timber framed buildings, contact your local buildings control

authority.

2. GAS SUPPLY

2.1 Before installation, ensure that the local distribution

conditions (identification of the type of gas and pressure)

and the adjustment of the appliance are compatible.

2.2 Ensure that the gas supply is capable of delivering the

required amount of gas and is in accordance with the rules

in force.

2.3 Soft copper tubing can be used to install the appliance. Soft

soldered joints can be used externally of the appliance.

2.4 This appliance is supplied complete with a factory fitted

isolation device incorporated into the inlet connection, no

further isolation device is required.

2.5 All supply gas pipes must be purged of any debris that may

have entered, prior to connection to the appliance.

2.6 The gas inlet is located centrally at the bottom of the

appliance. The supply pipe may be installed using one of

three alternatives.

1) By drilling a hole straight through the outside wall. There

is a cutout in the back panel of the Linea and the fixing

bracket to allow the pipe to be concealed within the

appliance.

2) Surface mounting the pipe. For this option there is a pipe

cover kit 8654. This consists of

a) 1.4 Metre Cover

b) 2 Brackets

c) Screws and Rawlplugs

To fit the cover, measure the length required and cut down

accordingly. Fix the two brackets to the wall as required.

The magnets should be vertical. Fix pipe clips to the wall

and install the gas pipe. The cover can now be attached to

the magnets to cover the gas supply.

NOTE: There are three options of cover finishes. Black,

Metallic Alloy and primed finish which allows the customer

to finish any chosen colour.

3) The gas pipe can be concealed by cutting a channel in

the wall. All current regulations must be adhered to and no

pipe joint must be concealed in the wall.

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

3. VENTILATION

3.1 This appliance requires no additional ventilation.

4. APPLIANCE LOCATION

IMPORTANT: DO NOT OBSTRUCT THE TOP AND BOTTOM

SLOTS IN THE LINEA OUTER CASE, THESE MUST BE

UNOBSTRUCTED. DO NOT RECESS THIS APPLIANCE

INTO A WALL, IT MUST BE SURFACE MOUNTED ON A

FLAT WALL USING THE WALL MOUNTING BRACKET

SUPPLIED.

4.1 This appliance does not require a hearth. It can only be

fitted on an outside wall with suitable clearances for the flue

terminal and guard (if required). As detailed in diagram 1.

4.2 All minimum clearances must be complied with. See

diagram 3. These clearances are to the outside edge of the

decorative frame and are therefore dependant on the frame

chosen.

4.3 The outer dimensions of the frames and their position

relative to the flue centre of the Linea are detailed in

diagrams 4 and 5.

3

AR1325

4

AR1326

DESIGNO

Advertising