EMERGENCY SHUT OFF

If the batteries fail during use of the fire:

• Move the emergency shut off switch to the OFF (O)

position

This emergency switch is located behind the slotted lower

panel on the underside of the appliance:

3

AR1341

Underside of appliance

Access to switch

• Use a ball point pen or narrow screwdriver to push the

rocker switch to the OFF (O) position, Diagram 4

4

AR1961

Emergency

Shut Off

(This switch is set to be ON (

|

) during normal operation

and must remain ON)

3. CLEANING THE LINEA

ENSURE THE APPLIANCE IS COLD BEFORE PROCEEDING.
3.1 The outside casing of the Linea should be cleaned using a

damp cloth.

3.2 To clean the glass panel, remove the decorative front as

detailed in the instructions supplied with front.

3.3 Remove the glass panel by unscrewing the nine pozidrive

screws, Diagram 5

6

USER INSTRUCTION

5

AR1339

3.4 Use a damp cloth and warm soapy water. Ensure the glass is

dry before re-assembling.

3.5 Ensure that the fibreglass seal on the firebox is intact then

hook the location tabs over the hooks on the top of the

firebox. Replace the nine screws working from the top

down, three long ones in the bottom holes. Tighten the

screws evenly.

NEVER OPERATE THE APPLIANCE WHEN THE GLASS

PANEL IS REMOVED OR BROKEN.

4. FLAME FAILURE DEVICE

4.1 This is a safety feature incorporated on this appliance which

automatically switches off the gas supply if the pilot goes

out and fails to heat the thermocouple.

5. RUNNING IN

5.1 The surface coating on the ceramic panel used in your

GAZCO fire will "burn off" during the first few hours of use

producing a harmless and temporary odour. This will

disappear after a short period of use. If the odour persists,

ask your installer for advice.

6. SERVICING

6.1 The fire must be serviced every 12 months by a qualified

Gas Engineer. In all correspondence always quote the

Model number and the Serial number which may be found

on the data badge.

7. VENTILATION

7.1 This appliance requires no additional ventilation.