WARNING: Power must be removed from the ASTAT-

IBP before any servicing operation.

AVERTISSEMENT: Le courant doit être enlevé du

ASTAT-IBP avant de procéder à toute opération de

service.

Cover Removal and Replacement

1. Remove the two 12-point terminal connectors by

inserting a flat-head screwdriver between the

terminal connector and the ASTAT-IBP cover, as

illustrated in Figure 1.
Do not remove the wiring from the terminal

connectors.
Carefully release the terminal connector from the

pins. Carefully pull the terminal connectors, with

the wiring, straight off the ASTAT-IBP starter.

2. Remove the plastic cover by pressing and releasing

the plastic tab on each side of the cover with a flat-

head screwdriver, as illustrated in Figure 2.

3. To reattach the cover, lower it over the circuit

boards. Carefully push down on the cover until the

two tabs snap into place. It may be necessary to push

in slightly on the outside of the lower plastic

housing.

4. Replace the terminal connectors through the plastic

cover onto the connector strips. Ensure that the

terminal connectors snap into place.