Dimensions & clearances, Installation of the range, Dimensions and clearances – GE 164D3333P185-1 User Manual

Page 24: Important safety instructions

Advertising
background image

Customer Service

Troubleshooting T

ips

Installation Instructions

Care and Cleaning

Operating Instructions

Safety Instructions

24

Installation of the range.

Read these instructions completely and carefully.

Dimensions and Clearances

Provide adequate clearances between the range and adjacent combustible surfaces.

Models

A

B

C

20

Wide

20

20

3

8

2

24

Wide

24

24

3

8

0

A

36

25-1/2

*

from wall
to front of
control panel

40

1

2

40

1

4

*Depth including handle: 25-9/16.

*

Depth to front of control knobs: 26-1/8.

36

0

clearance below cooking top and at rear of range

13

Maximum depth

for cabinets above

range top

36

18

Minimum to

cabinets on

either side

of range

30

B

C

Minimum to wall on

either side of range

above 36

height

Minimum

Important Safety Instructions

Installation of this range must conform with local
codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1, latest
edition. In Canada, installation must conform
with the current Natural Gas Installation Code,
CAN/CGA-B149.1 or the current Propane
Installation Code, CAN/CGA-B149.2, and with
local codes where applicable.

This range has been design-certified by the
American Gas Association according to ANSI
Z21.1, latest edition and Canadian Gas
Association according to CAN/CGA-1.1 latest
edition. As with any appliance using gas and
generating heat, there are certain safety
precautions you should follow. You will find
these precautions in the Important Safety
Instructions in the front of this guide. Read them
carefully.

A range should NOT be installed directly over

kitchen carpeting unless an insulating pad of

1/4-inch thick piece of plywood is placed

between the range and carpet.

Be sure your range is properly installed by a

qualified installer or service technician.

This range must be electrically grounded in

accordance with local codes, or in their

absence, with the National Electrical Code

ANSI/NFPA No. 70, latest edition and

Canadian Gas Association according to

CAN/CGA-1.1 latest edition. See Electrical

Connection Information.

Before installing the range in an area covered

with linoleum or any other synthetic floor

covering, make sure the floor covering can

withstand heat at least 90°F. above room

temperature without shrinking, warping or

discoloring.

Make sure the wall coverings around the range

can withstand the heat generated by the range.

Make sure all controls remain in the OFF

position when the range is not in use.

24