Read these instructions completely and carefully.

Convert Burner Orifices and Pressure Regulator (if necessary)

Converting Burner Orifices to LP Gas:

Tighten the orifice hoods for the surface burners

and oven burner approximately two complete

turns to the closed position and adjust top pilots,

if equipped. The gas pressure regulator must be

converted to the LP gas setting so that it will

provide a pressure of 10 inches water column to

the range manifold.

Converting Burner Orifices to Natural Gas:
(only if range has been operated previously on LP gas)

Unscrew the orifice hoods for all burners (top

and oven) approximately two complete turns,

until the flame on the burner does not increase in

length. Adjust the top pilots (if equipped). The

gas pressure regulator must be set to the natural

gas setting so that it will provide a pressure of 4

inches of water column in the range manifold.

Regulator Conversion:

All ranges are equipped with a gas pressure

regulator for controlling and maintaining a

uniform gas pressure in the gas manifold of the

range. The burner orifices are sized for the gas

pressure delivered by the regulator supplied.

The pressure regulator must not be removed.

To convert the regulator from one gas to another,

refer to the following illustration that applies:

Harper-Wyman Regulator:

For a Harper-Wyman regulator, remove converter

cap by inserting a coin into slot in top and

twisting. Turn cap over and re-install.

SCP Regulator:

On the SCP regulator, unscrew the converter

using a 5/8

wrench. Turn the cap over and

reinstall.
NOTE: What you read on the converter cap or plunger is
the type of gas for which the regulator is set. If yours reads
NAT, the regulator is set for natural gas. If yours reads LP,
the regulator is set for LP.

For proper operation, the maximum inlet pressure

to the regulator must be no more than 14 inches of
water column pressure.

For checking the

regulator, the inlet pressure must be at least

1-inch of water column (3.4 KPA) greater than

the regulator output setting. If the regulator is

set for 4 inches of water column pressure, the

inlet pressure must be at least 5 inches. If the

regulator is set for 10 inches, the inlet pressure

must be at least 11 inches.

The gas supply line to the range should be 1/2

inch or 3/4 inch pipe.

For standing pilot models,

make the necessary oven

pilot adjustment (see directions in the If Range
Has Standing Pilots—Light and Adjust Surface
Burner Pilots

section). Also burner air shutter

adjustments may be necessary on all models to

complete conversion (see the Surface Burner Air
Shutter Adjustment

section).

LP gas setting

NAT. gas setting

NAT

LPG

NAT

LPG

Converter cap