3-Wire Conduit Installation

Remove the 3 screws from the connector block.

Insert bare wires between the connector block

terminals and movable nuts. Tighten screws

securely. Do not remove ground strap connection.

WARNING:

Connector block is approved for

copper wire connection only. If aluminum wire
is used, see note below.

NOTE: ALUMINUM WIRING

A.

Do not connect aluminum wire to the connector

block.
Use copper building wire rated for the correct

amperage and voltage to make three 3

copper

jumper wires. Connect wire as per Step 6 or 7

depending on number of wires.

B.

Splice copper wires to aluminum wiring using

special connector terminals designed and

UL-approved for joining copper to aluminum

and follow the connector manufacturer’s

recommended procedure closely.

Wire used, location and enclosure of splices, etc., must
conform to good wiring practices and local codes.

4-Wire Power Cord Installation

WARNING:

The neutral wire of

the supply circuit is connected to the neutral
terminal located in the center of the connector
block. The power leads must be connected to
the outside (brass-colored) terminals. The 4th
grounding lead must be connected to the
frame of the range with the grounding plate
and grounding screw.

A.

Remove the 3 screws from the connector block.

B.

Remove the grounding screw and strap from the

connector block middle location and the screw

connection to the frame of the range.

C.

Insert screws through each power cord terminal

ring and into connector block until screw

engages nut. Be certain that the center wire is

connected to the center screw of the connector

block. Tighten screws securely.

D.

Attach ground wire to the frame of the range.

Before

After

Neutral terminal

Ground Strap
(grounding to range)

Grounding to range

Grounding
plate

Neutral terminal

Bare wire tips

Conduit

Connector block

Bracket

Screw

Flexible cable

Bare wire

Movable nut

Connector block
terminal

Read these instructions completely and carefully.