Blade tensioner – Grizzly G0555X User Manual

Page 46

Advertising
background image

-44-

g0555X

(Mfg. since 1/12)

Blade Tensioner

over the life of the machine, the blade tensioner
system may need to be reset for correct opera-
tion.

To reset the blade tensioner:

1. disConneCt bandsaW FroM poWer!

2. release the tension lever shown in figure 50

and remove the bandsaw blade.

4. loosen the setscrews in both of the spacers

indicated in

figure 51.

5. back the spacers away from the tension lever

crossbar shown in

figure 50.

6. pull the tension lever down to the horizontal

position.

7. pull up on the tensioning knob (figure 50)

until the blade touches the wheel.

8. thread the upper spacer down until it touches

the top of the tension lever crossbar.

9. tighten the setscrew on the upper spacer.

10. tension the blade (refer to page 20).

11. thread the lower spacer down until it touches

the top of the sliding bracket indicated in

figure 51.

12. Move the lower spacer back up the shaft

about 1-2 turns to leave a small space, and
tighten the setscrew (

figure 51).

13. Make sure there is no tension on the blade

when the lever is released. if all the tension
is not released, the lower spacer needs to be
threaded farther down the shaft toward the
sliding bracket.

figure 50. blade tension controls/components.

tension lever

tensioning

Knob

tension lever

Crossbar

figure 51. loosening the spacer set screws.

upper

spacer

lower

spacer

sliding

bracket

3. place the new blade onto the wheels and

between the blade guide bearings.

Note: A new blade is used to calibrate the
tensioner because it is unstretched.

Advertising