For Help, call 1-800-35-GENIE or visit www.geniecompany.com

NOTE

During the next adjustment, if the door stops during

opening or reverses during closing before reaching the

limits, the door force must be adjusted.Change the door

force setting as described in the next section then return

here to finish setting these limits.

WARNING: TO REDUCE THE

RISK OF SEVERE INJURY OR DEATH

1

READ AND FOLLOW ALL INSTRUCTIONS.

2

Never let children operate or play with the Door Controls.

Keep the Remote Control away from children.

3

Always keep the moving door in sight and away from

people and objects until the door is completely closed.

NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR.

4

NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

5

Test Opener monthly. The door MUST reverse on contact

with a 1-1/2" high object (or a 2" x 4" board laid flat) at the

center of the doorway on the floor. After adjusting either

the Force or the Limit of travel, retest the Door Opener.

Failure to adjust the Opener properly may cause severe

injury or death.

6

When possible use the Emergency Release only when the

door is closed. Use caution when using this Release with

the door open. Weak or broken springs are capable of

increasing the rate of door closure and increasing the risk

of severe injury or death.

7

KEEP GARAGE DOORS PROPERLY BALANCED. See Owner's

Manual. An improperly balanced door increases the risk of

severe injury or death. Have a Genie Factory Authorized

Dealer make repairs to cables, spring assemblies, and

other hardware.

8

SAVE THESE INSTRUCTIONS.

IMPORTANT SAFETY

INSTRUCTIONS

A

DJUSTING AND

T

ESTING THE

F

ORCE

C

ONTROLS

C

ONTINUED

Step 6:

A

Locate the OPEN FORCE adjustment screw (Figure 3).

Use the remote control to cycle the door during these tests.

Start with the door closed.

Turn the open force adjustment screw 1/8-turn at a time in the
decrease direction until the door stops midway while opening..

Turn the open force adjustment 1/8-turn at a time in the
increase direction until the door fully opens without stopping.

Figure 3 Open force adjustment

Figure 2 Checking safety reverse

A

Locate the CLOSE FORCE adjustment screw (Figure 1).

Use the remote control to cycle the door during
these tests.

Start with the door open.

Turn the close force adjustment screw 1/8-turn at a time
in the decrease direction until the door reverses midway
while closing.

Turn the close force adjustment 1/8-turn at a time in the
increase direction until the door fully closes
without reversing.

Figure 1 Adjusting close force

NOTE

Very light, well balanced doors may not be able to be

adjusted using the above steps. If so, set the close

force to minimum.

TEST THE SAFETY REVERSE
B

To test the safety reverse (Figure 2).

Open the garage door.

Lay a 2" x 4" board flat so it will be struck by the center of
the door as it closes.

Using the remote control, close the door.

The door must reverse within 2 seconds of hitting
the board.

If the door stops but does not reverse, the close force
must be decreased.

Repeat this test until the door reverses as required.