6

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Source

Sensor

Safe-T-Beam®

Mounting Bracket

Top of

Bracket 6"

above

floor

Figure 7 Mounting Safe-T-Beam® Components

Figure 8 Recommended Tools

Go to Assembly and Installation Poster for full
Installation Instructions.

C

HECK

C

EILING FOR

G

ROUNDED

P

OWER

S

OURCE

Check Step 6:

NOTE

Permanent wiring must be installed by a Licensed

Electrician. Not all Genie Factory Authorized Dealers

are Licensed Electrician's. Contact someone who is a

Licensed Electrician.

WARNING

Do Not use an extension cord! Extension cords can

cause dangerous overheating conditions.
Do Not use portable generator! This product is

designed to operate using standard house current.

Do

Not use alternate power supplies,

A

Check that there is a 15 Amp 120 Volt grounded electrical

outlet or grounded permanent wiring box (per building code)
within 3' of Opener Power Head:

If not, an outlet or wiring box must be installed. Contact
a licensed electrician for installation.

If building codes require permanent wiring, Power Head
must be partially disassembled to install appropriate
wiring in place of Power Cord. See Assembly and
Information Poster.

C

HECK

S

AFE

-T-B

EAM

®

M

OUNTING

B

RACKET

L

OCATION

Check for wood garage frame, jamb, or masonry at mounting
location (6" above floor) with attachment tabs facing away
from garage door (

Figure 7).

A

If you cannot mount Safe-T-Beam® Mounting Bracket to

wood frame:

Concrete screws and concrete anchors (not included)
must be used to mount Brackets on masonry with
attachment tabs facing away from garage door.

Check Step 7:

R

ECOMMENDED TOOLS

A

Tools (Figure 8):

B

Additional tools to make installation easier:

Slotted and phillips screw-driver bits

Stud finder

Sheet-metal cutting snips

Check Step 8:

D

R

EMOVE

E

XISTING

G

ARAGE

D

OOR

L

OCKS

Check that the garage door locks, rope, and T-Handles are
removed from the garage door before starting the installation.

A

If your garage does not have a separate entry door, it is

highly recommended to install a Genie Emergency Release Kit
(GER-2). Emergency Release Kit lets you open the garage door
from outside if there is a power failure. (Please see Accessories
Order Form on page 23.)

Check Step 9:

Before going further, get any items and tools needed for
your installation

Garage door frame reinforcement brackets, screws, bracing
or reinforcement kits (dealer)

Lag Screws (1-1/4") for a wood door less than 2" thick (store)

Electrical outlet and/or wiring (supplied by a licensed electrician)

Sufficient angle iron or strapping for hanging Power Head (store)

100 Watt light bulb (Rough service bulbs recommended)(store)

GER-2 Emergency Release Kit for entry during power failure (store)

Wood for header, ceiling, and/or door bracing reinforcement
(if needed)

Masonry fasteners for Safe-T-Beam® Bracket installation, (if needed)

Masonry drill bit (if needed)

Extension Kit (for 8’ Garage Doors)