Appendix b – Gefen 8x8 EXT-DVI-848 User Manual

Page 25

Advertising
background image

22

APPENDIX B

Unmask Masked Outputs
This function unmasks outputs that were masked by “#MASK”

#UNMASK_param1[_param2][_param3][_param4][_param5]

[_param6][_param7][_param8]\r

Parameter

Name

Value

1 (2-8 optionally)

MONITOR

[A : H]

RMT-848IR Address
This function set the remote channel that must match the GEFEN RMT-848IR
remote control.

#RMT_param1\r

Parameter

Value

1

[0:3]

DS EDID Store In Locals Edid
This function reads EDID fi le from DS and store it in any input Locals EDID.

#EDIDDSTOLO_param1_param2[_param3][_param4][_param5] [_param6]

[_param7][_param8][_param9]\r

Parameter

Name

Value

1

MONITOR

[A:H]

2 (3-9 optionally)

INPUT

[1:8]

DS EDID Store In EDID Bank
This function reads EDID fi le from DS and store it in EDID bank.

#EDIDDSTOBA_param1_param2\r

Parameter

Name

Value

1

MONITOR

[A:H]

2

EDID bank offset

[1:7]