GE E4H-CE Series User Manual

Page 13

Advertising
background image

1.4.1

Feed Water Specifications

The feed water requirements listed in Table 1.1 must be met to ensure quality per-
meate and extended membrane element life.

1.4.2

Permeate Flow Rate

Stated in Table 1.1 and on the machine serial number label (assumes no permeate
back pressure, 2000 mg/L Total Dissolved Solids (TDS) maximum feed concen-
tration, and rated temperature).

To estimate permeate output with back pressure, use the formula below.
Maximum permeate back pressure is 80 psig (5.5 bar).

(Specified Permeate) x [(Operating Pressure) - (Permeate Back pressure)]

(Operating Pressure)

1.4.3

Concentrate Flow Rate

Stated in Table 1.1 and factory-set as stated on the serial number label.

1.4.4

Pressure Range

The Pressure Ranges listed below (Table 2.1) are boost pressure:

Boost Pressure = [(Primary Pressure - (Post-Filter Pressure)].

Table 1.2

Minimum/Maximum (Min/Max)

Boost Pressure

8

MODEL

E4H-CE-3

E4H-CE-5

E4H-CE-7

E8-CE-9

E8-CE-14

E8-CE-23

PUMP MODEL

Tonkaflo, SS2823G-50

Tonkaflo, SS2823G-50

Tonkaflo, SS2823G-50

Tonkaflo, SS2823G-50

Tonkaflo, SS2823G-50

PRIMARY PRESSURE

RANGE bar (psi)

8.6 - 15.5 (125 - 225)

7.6 - 15.5 (110 - 225)

6.6 - 14.4 (100 - 210)

6.6 - 12.8 (95 - 185)

5.2 - 9.3 (75 - 135)

Advertising