GE E4H-CE Series User Manual

Page 30

Advertising
background image

6.0

TROUBLESHOOTING

This troubleshooting guide can assist you in identifying common operating problems you may
experience with your machine. The operator can easily correct many of these problems, howev-
er, for those that persist or are not understood you should contact the GE Osmonics Customer
Support Center. Have the following information available when calling the Customer Support
Center:

1. Machine installation date
2. Model number
3. Serial number
4. Detailed description of problem

SYMPTOM

Low operating pressure

POSSIBLE CAUSES

Insufficient feed water pressure

flow

Clogged pre-filter

High flow rates

Dirty or fouled membrane

elements

Solenoid valve not opening

Pump rotating backwards

(three-phase power only)

REMEDIES

Open the feed pressure, open

the feed water valve, and

check for restrictions.

Replace pre-filter cartridge.

Close the concentrate valve,

check the permeate and con-

centrate flow rates and adjust

if necessary. Excessive per-

meate flow may indicate a

damage O-ring.

Flush and clean the membrane

elements.

Clean or replace the solenoid

valve.

Switch any two three-phase

leads to the motor starter.

25

TROUBLESHOOTING

Advertising
This manual is related to the following products: