Extension Cords

We do not recommend using an extension cord
with this machine. If you must use an extension
cord, only use it if absolutely necessary and only
on a temporary basis.

Extension cords cause voltage drop, which may
damage electrical components and shorten motor
life. Voltage drop increases as the extension cord
size gets longer and the gauge size gets smaller
(higher gauge numbers indicate smaller sizes).

Any extension cord used with this machine must
contain a ground wire, match the required plug
and receptacle, and meet the following require-
ments:

Minimum Gauge Size ...........................14 AWG

Maximum Length (Shorter is Better).......50 ft.

Grounding Requirements

This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.

figure 2. typical 5-15 plug and receptacle.

Grounding Prong

Neutral Hot

5-15 PLUG

GROUNDED

5-15 RECEPTACLE

SHOCK HAZARD!

Two-prong outlets do not meet the grounding

requirements for this machine. Do not modify

or use an adapter on the plug provided—if

it will not fit the outlet, have a qualified

electrician install the proper outlet with a

verified ground.

for 120v operation: this machine is equipped
with a power cord that has an equipment-
grounding wire and a grounding plug (see follow-
ing figure). the plug must only be inserted into a
matching receptacle (outlet) that is properly
installed and grounded in accordance with all
local codes and ordinances.