Table tilt calibration – Grizzly G0702 User Manual

Page 24

Advertising
background image

-22-

Model g0702 (Mfg. since 1/12)

Note: This can be done with the sandpaper
installed, although it is somewhat more pre-
cise if the sandpaper is not installed.

3. loosen the lock levers and adjust the table

angle until it is perfectly perpendicular to the
disc, then tighten the lock levers while hold-
ing the table in place.

4. using a phillips head screwdriver, loosen the

degree scale pointer, index the pointer on 0˚,
and retighten the screw.

5. recheck the scale accuracy with the square.

When the table tilt is set to 90˚, the table should
be positioned perpendicular to the sanding disc
face. if not follow this procedure.

to calibrate the table tilt:

1. diSConnECt MaChinE FroM poWEr!

2. using a try square or machinist’s square, set

one edge on the table surface and the other
against the face of the disc, as shown in

figure 19.

table tilt Calibration

figure 19. Squaring the table.

tilt Scale and

pointer

Advertising