Important safety instructions, For your safety, Electrical requirements – GE ZET2 User Manual

Page 2: Installation instructions, Warning, Avertissement

Advertising
background image

2

IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions

For Your Safety

• Be sure your oven is installed properly by

a qualified installer or service technician.

• Be sure the oven is securely installed in a

cabinet that is firmly attached to the house
structure. Weight on the oven door could
cause the oven to tip and result in injury.
Never allow anyone to climb, sit, stand or
hang on the oven door.

• Make sure the cabinets and wall coverings

around the oven can withstand the
temperatures (up to 200

°

F) generated

by the oven.

This appliance must be supplied with the
proper voltage and frequency, and connected
to an individual, properly grounded branch
circuit, protected by a circuit breaker or fuse
having amperage as noted on rating plate.

We recommend you have the electrical
wiring and hookup of your oven connected by a
qualified electrician. After installation, have the
electrician show you where your main oven
disconnect is located.

Check with your local utilities for electrical
codes which apply in your area. Failure to wire
your oven according to governing codes could
result in a hazardous condition. If there are no
local codes, your oven must be wired and fused
to meet the requirements of the National
Electrical Code, ANSI/NFPA No. 70–Latest
Edition. You can get a copy by writing:

National Fire Protection Association
Batterymarch Park
Quincy, MA 02269

Effective January 1, 1996, the National
Electrical Code requires that new, but not
existing, construction utilize a four-conductor
connection to an electric oven. When installing
an electric oven in new construction, a mobile
home, recreational vehicle or an area where
local codes prohibit grounding through the
neutral conductor, follow the instructions in
the section on NEW CONSTRUCTION AND
FOUR-CONDUCTOR BRANCH CIRCUIT
CONNECTION.

You must use a three-wire, single-phase A.C.
208Y/120 Volt or 240/120 Volt, 60 hertz
electrical system. If you connect to aluminum
wiring, properly installed connectors approved
for use with aluminum wiring must be used.

WARNING:

The electrical

power to the oven supply line
must be shut off while line

connections are being made. Failure
to do so could result in serious injury
or death.

Electrical
Requirements

These Monogram built-in ovens require a
separate, properly grounded 3-wire 120/208 or
120/240 volt, 60 Hz power supply, protected by
a time delay fuse or circuit breaker.

• Double ovens are rated at 8.6 KW at 240 volt

and 7.8 KW at 208 volt.

• Single ovens are rated at 4.3 KW at 240 volt

and 3.9 KW at 208 volt.

AVERTISSEMENT :

Vous devez couper l’alimentation
électrique du four avant de le

brancher. Le défaut de se conformer
à cette procédure peut entraîner des
blessures sévères et même la mort.

Rating Plate
Location

Advertising