GEAppliances.com

Temperature Limiting

(Requires room air sensor kit–RAVRMS)

Temperature limiting can reduce energy costs

by limiting the lowest temperature that can be

set for cooling and the highest temperature that

can be set for heating. Temperature limiting is

controlled by switches 1–6 on the top block

of auxiliary controls. The first three switches are

used to select the cooling limits. The next three

switches are used to control the heating limits.

Temperature limiting during COOL mode

(all temperatures shown in °F)

UP

DOWN

Minimum

Maximum

NONE

1, 2, 3

60°

85°

1

2, 3

64°

85°

1, 2

3

66°

85°

2

1, 3

68°

85°

2,3

1

70°

85°

1, 2, 3

NONE

72°

85°

1, 3

2

74°

85°

3

1, 2

76°

85°

Temperature limiting during HEAT mode

(all temperatures shown in °F)*

UP

DOWN

Minimum

Maximum

NONE

4, 5, 6

60°

85°

4

5, 6

60°

80°

4, 5

6

60°

78°

5

4, 6

60°

76°

5,6

4

60°

74°

4, 5, 6

NONE

60°

72°

4, 6

5

60°

70°

6

4, 5

60°

65°

* Not applicable to Cool-Only models