Function tests, At the ground controls, Do not operate unless – Genie Z-34 User Manual

Page 16: Fundamentals

Advertising
background image

14

Genie Z-34/22 Bi-Energy

Part No. 56011

Operator's Manual

First Edition • Fifth Printing

1 Select a test area that is firm, level and free of

obstruction.

At the Ground Controls

2 Turn the key switch to ground control.

3 Pull out the red Emergency Stop button to

the on position.

Result: The beacon (if equipped) should flash.

4 Start the engine. See Operating Instructions

section.

Test the Emergency Stop

5 Push in the red Emergency Stop button to the

off position.

Result: The engine should turn off and all

functions should not operate.

6 Pull out the red Emergency Stop button to

the on position.

Test the Machine Functions

7 Do not hold the function enable switch to either

side. Attempt to activate each boom and
platform function toggle switch.

Result: All boom and platform functions should

not operate.

8 Hold the function enable switch to either side

and activate each boom and platform function
toggle switch.

Result: All boom and platform functions should

operate through a full cycle. The descent alarm
(if equipped) should sound while the boom is
lowering.

Machines equipped with Platform Level Control
Disable Function: The platform level toggle switch
will not operate when the primary boom is raised
past the drive speed limit switch.

Function Tests

Do Not Operate Unless:

You learn and practice the principles of safe

machine operation contained in this operator's
manual.

1 Avoid hazardous situations.

2 Always perform a pre-operation

inspection.

3 Always perform function tests prior to

use.

Know and understand the function tests

before going on to the next section.

4 Inspect the workplace.

5 Only use the machine as it was intended.

Fundamentals

The function tests are designed to discover any
malfunctions before the machine is put into service.
The operator must follow the step-by-step
instructions to test all machine functions.

A malfunctioning machine must never be used. If
malfunctions are discovered, the machine must be
tagged and removed from service. Repairs to the
machine may only be made by a qualified service
technician, according to the manufacturer's
specifications.

After repairs are completed, the operator must
perform a pre-operation inspection and function
tests again before putting the machine into service.