g0669X precision 10" x 54" Vs Milling Machine

-39-

Ram Way

Lubricant

frequency

Qty

iso 68 sae 20W
Bearing and gear
Lubricant

every
40 hours
of operation

thin
Coat

Move the ram forward and backward as neces-
sary to access the entire length of the ram way
(see

figure 55). Use mineral spirits and shop rag

to wipe the old lubricant and debris from the way
surfaces, then brush on a thin coat of lubricant.

Longitudinal Power feed Gearing

Lubricant

frequency

Qty

Multi-purpose gear
grease

every 120
hours of
operation

thin
Coat

remove the right longitudinal ball handle, spac-
ers, and leadscrew keys. slide the graduated dial
assembly out from the power feed unit. apply a
thin coat of lubricant to the brass and drive gears
shown in

figure 56, then re-install the parts in

reverse order.

figure 56. Longitudinal power feed gearing.

Brass gear

drive gear

Vertical Leadscrew bevel Gears

Lubricant

frequency

Qty

Multi-purpose
gear grease

every
40 hours
of operation

thin Coat

open the access panel on the front of the saddle
shown in

figure 57. Using mineral spirits and a

shop rag, reach through the opening and clean
old lubricant and debris from the vertical bevel
gears. apply a thin coat of lubricant, then replace
the access panel.

figure 57. Vertical leadscrew bevel gears.

access panel

Bevel

gears

Keys

figure 55. ram way.

ram Way