VENT EXAMPLES FOR SINGLE FLUE (cont.)

FLEXIBLE
FLUE KIT

FLEXIBLE GAS
LINE

PVC PIPE SWV
(SUPPLIED BY INSTALLER)

(2) - 45 DEG. PVC BENDS
(SUPPLIED BY INSTALLER
IF NECCESSARY)

GALV. SHEET FLASHING
TO SEAL CHIMNEY
(SUPPLIED BY INSTALLER)

VENT CAP (SUPPLIED
WITH VENT KIT)

H

12

X

ROOF PITCH
IS

12

X

17’

5.2m

Figure 22

Venting for Existing Fireplace Installation

Determining Minimum Vent Height Above the Roof
WARNING:
Major U.S. building codes specify minimum chim-

ney and/or vent height above the rooftop. These minimum heights

are necessary in the interest of safety. These specifications are

summarized in Figure 22.

90° =

3’

V =

17’

Total =

20’

ROOF PITCH

H (Min.)

Flat to 6/12

12” (305mm)

6/12 to 7/12

15” (381mm)

Over 7/12 to 8/12

18” (457mm)

Over 8/12 to 16/12

24” (610mm)

Over 16/12 to 21/12 36” (914mm)