Installation

Built-In Ovens

16

• Outlet box

• Electrical cable—3-conductor or 4-conductor wire—as required

by local codes

• Flexible power cable connector

• Electrician’s pliers

Note:

Do not use an extension

cord with these appliances.

Monogram built-in single and double ovens require
a separate, properly grounded 3-wire 120/208 or 120/
240 volt, 60 Hz power supply, protected by a time
delay fuse or circuit breaker. Ovens are supplied with a
flexible power cable, which must be attached to a
junction box. The cable length is 48" for both single
and double conventional ovens. The cable length for
convection type ovens is 54".

Double ovens are rated 6.8 KW at 240 volt, and 5.1 KW
at 208 volt.
Single ovens are rated 3.4 KW at 240 volt, and 2.6 KW
at 208 volt.

Tools and
materials
required

The back of the ovens have chamfered corners which
provide a “chase” for the conduit when installing a
junction box above or below the oven(s).

The conduit is located on the back of the oven,
approximately 10" from the right side.

For double oven:
• Locate and install the junction box within reach of

the power cord.
– Approximately 10" from the left side of opening
– 56" minimum above the cutout floor
– or, through the left side of cabinet wall into

adjacent cabinet.

For single oven:
• Locate and install the junction box within reach of

the power cord.
– Approximately 10" from left side of opening.
– At least 5" below the cutout floor
– Or 34" minimum above the cutout floor
– or, through the left side of cabinet wall into

adjacent cabinet.

Double Oven:

Locate Junction Box

in one of the locations

Single Oven:

Locate Junction Box

in one of the locations

Electrical
locations

Advertising