Installation instructions, Warning, Electrical requirements for electric dryers – GE PFMN445 User Manual

Page 23: Grounding instructions

Advertising
background image

23

Installation Instructions

ELECTRICAL REQUIREMENTS

FOR ELECTRIC DRYERS

This dryer must be connected to an individual

branch circuit, protected by the required time-

delay fuses or circuit breakers. A three- or four-

wire, single-phase, 120/240V, 60Hz, 30-amp

circuit is required.
If the electric supply does not meet the above

specifications, then call a licensed electrician.

GROUNDING INSTRUCTIONS

This dryer must be connected to a grounded metal,

permanent wiring system, or an equipment-

grounding conductor must be run with the circuit

conductors and connected to the equipment

grounding terminal on the appliance.

CONNECTING DRYER USING 4-WIRE

CONNECTION (MUST BE USED FOR

MOBILE HOME INSTALLATION)

NOTE: Since January 1, 1996, the National Electrical

Code requires that new constructions utilize a

4-wire connection to an electric dryer. A 4-wire cord

must also be used where local codes do not permit

grounding through the neutral.
3-wire connection is NOT for use on new

construction.

Remove ground
strap and
discard. Keep
green ground
screw

Hot Wire

Relocate green ground
screw here

Green Wire

Strain Relief
Bracket

3/4″ UL Recognized
Strain Relief

Hot Wire

Neutral
(white)

Screws (3)

Cover

4 #10 AWG minimum copper
conductors or 120/240V 30A power
supply cord kit marked for use with
dryers and provided with closed loop
or spade terminals with upturned
ends (not supplied)

CONNECTING DRYER USING 4-WIRE

CONNECTION (MUST BE USED FOR

MOBILE HOME INSTALLATION) (cont.)

WARNING –

NEVER LEAVE THE

COVER OFF OF THE TERMINAL BLOCK.

1. Turn off the circuit breaker(s) (30 amp) or remove

the dryer’s circuit fuse at the electrical box.

2. Be sure the dryer cord is unplugged from

the wall receptacle.

3. Remove the power cord cover located at

the lower back.

4. Remove and discard ground strap. Keep

the green ground screw for Step 7.

5. Install 3/4 in. UL-recognized strain relief to power

cord entry hole. Bring power cord through strain

relief.

6. Connect power cord as follows:

A. Connect the 2 hot lines to the outer screws

of the terminal block (marked L1 and L2).

B. Connect the neutral (white) line to the center

of the terminal block (marked N).

7. Attach ground wire of power cord with the green

ground screw (hole above strain relief bracket).

Tighten all terminal block screws (3) completely.

8. Properly secure power cord to strain relief.
9. Reinstall the cover.