Installation instructions, Warning, Connecting an electric dryer (cont.) – GE PFMN445 User Manual

Page 24: Connecting dryer using 3-wire connection

Advertising
background image

Installation Instructions

If required, by
local code,
install external
ground (not
provided) to
grounded
metal, cold
water pipe,
or other
established
ground
determined
by a qualified
electrician.

Hot Wire

Strain
Relief
Bracket

3/4″ UL
Recognized
Strain Relief

Hot
Wire

Neutral
(white)

Screws (3)

Cover

3 #10 AWG minimum copper
conductors or 120/240V 30A power
supply cord kit marked for use with
dryers and provided with closed loop
or spade terminals with upturned ends
(not supplied)

Green Ground
Screw

Ground
Strap

CONNECTING DRYER USING 3-WIRE

CONNECTION

1. Turn off the circuit breaker(s) (30 amp) or remove

the dryer’s circuit fuse at the electrical box.

2. Be sure the dryer cord is unplugged from the

wall receptacle.

3. Remove the power cord cover located at the

lower back.

4. Install 3/4-in. UL-recognized strain relief to power

cord entry hole. Bring power cord through strain

relief.

5. Connect power cord as follows:

A. Connect the 2 hot lines to the outer screws

of the terminal block (marked L1 and L2).

B. Connect the neutral (white) line to the center

of the terminal block (marked N).

6. Be sure ground strap is connected to neutral

(center) terminal of block and to green ground

screw on cabinet rear. Tighten all terminal block

screws (3) completely.

7. Properly secure power cord to strain relief.
8. Reinstall the cover.

WARNING –

NEVER LEAVE THE

COVER OFF OF THE TERMINAL BLOCK.

CONNECTING AN ELECTRIC DRYER (cont.)

24

Advertising
This manual is related to the following products: