Installation instructions, Installation, Control upgrade – Stovax 705088 User Manual

Page 10: Safety precautions, Installation of the stove flue pipe installation

Advertising
background image

10

IMPORTANT: ENSURE THAT THE APPLIANCE IS

CORRECTLY ADJUSTED FOR THE GAS TYPE AND

CATEGORY APPLICABLE IN THE COUNTRY OF USE.

REFER TO DATABADGE AND TECHNICAL

SPECIFICATIONS OF THIS BOOKLET. FOR DETAILS OF

CHANGING BETWEEN GAS TYPES REFER TO SECTION

11, REPLACING PARTS.

1. CONTROL UPGRADE

1.1 This stove is fitted with a control valve that can be easily

upgraded to battery powered remote control. There are two

versions of this control which can be obtained through your

local Gazco stockist.

1.2 This upgrade can be fitted before or after installation but if

side clearances are limited then it will be easier to upgrade

the stove before installation. Full instructions are included

with the kit.

1.3 STANDARD REMOTE CONTROL

This remote control can control the gas appliance after the

pilot has been lit. It can turn the main burner on and

regulate it from low through to high and back again. It can

turn the main burner off leaving the pilot burning. GAZCO

PART NUMBER 8455.

1.4 THERMOSTATIC AND TIMER REMOTE CONTROL

This remote control can control the gas appliance after the

pilot has been lit. In "MANUAL MODE" it can be used to

turn the main burner on and manually regulate it from low

through to high and back again. It can also be used to turn

the main burner off leaving the pilot burning. In "AUTO

MODE" it will automatically regulate the room temperature.

In "TIMER MODE" it will turn the fire on and off according

to a pre-set programme and automatically regulate the room

temperature during two on periods. GAZCO PART NUMBER

8456.

2. SAFETY PRECAUTIONS

2.1 This appliance must be installed in accordance with the rules

in force, and used only in a sufficiently ventilated space.

Place read these instructions before installation and use of

this appliance.

2.2 All the instructions must be left intact with the user.
2.3 In your own interests and those of safety, this appliance must

be installed by a competent person in accordance
with local and national codes of practice. Failure to install

the appliance correctly could lead to prosecution.

2.4 This appliance is intended for use on a governed gas

installation and set to the required pressure.

2.5

Keep all plastic bags away from young children.

2.6 Do not place any object on or near to the stove. Allow

adequate clearance above the stove. See diagram 2 Site

Requirements, Appliance Location.

2.7 The stove is fitted with the Gazco Flue Sure System, which

will act to cut off the gas supply to the appliance in the

event of incorrect operation of the flue. If the system acts to

shut off the gas supply, this indicates that there is insufficient

flue pull. If this occurs a minimum of 10 minutes should be

allowed before trying to relight. Continued operation of this

safety device means that there may be a serious problem

with the flue system; a qualified gas engineer should inspect

this. DO NOT USE THE STOVE UNTIL AN ENGINEER SAYS

IT IS SAFE TO DO SO.

2.8 The Flue Sure System must not be tampered with. Use only

genuine Gazco replacement parts when servicing the system

- refer to Servicing section, Replacing Parts.

3. INSTALLATION OF THE STOVE

FLUE PIPE INSTALLATION

3.1 Open the carton and remove accessory carton and stove

unit. It will now be necessary to decide upon top or rear flue

exit, the stove is factory built for rear flue exit, but it may be

changed to top exit by using the following method.

3.1.1 Remove the flue spigot from the rear of the stove and

replace with the blanking plate from the top of the stove and

vice versa.

3.2 Position the stove ensuring all appropriate clearances are

observed. NOTE: The stove lid is loose, remove when

moving the unit. Using a pencil, mark the position of the

holes in the fixing brackets attached to the inside of the rear

legs.

3.3 Remove the stove and drill the holes using a number 12

masonry drill. Push rawlplugs into the holes and insert the

woodscrews until the head is approximately 3mm proud of

the hearth. Place the stove in position over the bracket so

that the screw heads locate in the large part of the slot. Push

the stove back so that the screw heads engage fully into the

narrow part of the slot, tighten the screws if desired.

3.4 Having run the gas supply to the stove, PURGE THE SUPPLY

PIPE, this is essential to expel any debris that may block the

gas controls. Connect the gas supply to the 8mm

compression elbow at the right-hand rear corner of the

stove. There is a cutout in the right-hand rear leg to enable a

direct straight connection to be made to the rear of the

stove. See diagram 1. A gas soundness check must be

completed up to the gas inlet connection.

3.5 Check the pull of the flue system by applying a lighted

smoke pellet to the flue system opening. If there is a definite

flow into the chimney, proceed with the installation. If not,

warm the chimney for a few minutes.
IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY

REQUIRE ATTENTION - SEEK EXPERT ADVICE

INSTALLATION INSTRUCTIONS

INSTALLATION

1

AR0934

Advertising