User instructions, General, Lighting the stove – Stovax 705088 User Manual

Page 4

Advertising
background image

4

USER INSTRUCTIONS

1. GENERAL

1.1 Installation and servicing must be carried out by a

competent person in accordance with Gas Safety (Installation

and Use) Regulations 1998, the relevant British Standards for

Installation, appropriate Codes of Practice and in accordance

with the manufacturer’s instructions. It is recommended that

a CORGI registered engineer be used for this purpose as

they are approved by the HSE under the above regulations.

1.2 This appliance is suitable for use in G.B. and I.E. using

Natural Gas at a supply pressure of 20mbar or LPG at a

supply pressure of 29mbar (Butane) or 37mbar (Propane).

1.3 The installation shall also be completed in accordance with:

The Building Regulations issued by The Department of The

Environment.
The Building Standards (Scotland) Regulations issued by the

Scottish Development Department. For Republic of Ireland,

reference should be made to the relevant standards

governing installations (IS813:1996)

1.4 Read all these Instructions before commencing installation.
1.5 This appliance must be installed in accordance with the rules

in force and only used in a sufficiently ventilated space.

1.6 Ensure that curtains are not positioned above the stove, and

that there is at least a clearance of 300mm between the

sides of the stove and any curtains.

1.7 The manufacturer considers the full outer casing of this stove

to be a working surface. Therefore it will become hot whilst

in operation. A suitable guard is recommended to protect

young children, the aged and the infirm.

1.8 This stove must only be operated with the door secured

firmly in position. If any cracks appear in the glass the

appliance must not be used until the glass panel is replaced.

1.9 Do not attempt to burn rubbish in this stove.
1.10 Any combustible shelves or surrounding furniture must only

be fitted in accordance with the minimum dimensions

detailed in Diagram 1.

1.11 Contact a competent service engineer to carry out relevant

spillage checks etc. following home improvements carried

out after installation of this stove (e.g. the fitting of double

glazing).

1.12 In all correspondence, please quote the appliance type and

Serial Number which can be found on the databadge at the

rear of the stove.

1.13 This product is guaranteed for 2 years from the date of

installation, as set out in the terms and conditions of sale

between Gazco and your local Gazco dealer. Please consult

with your local Gazco dealer if you have any questions. In

all correspondence always quote the Model No. and Serial

No. Please ensure the commissioning checklist is completed

by your installer, as this is a requirement of your Guarantee.

2. LIGHTING THE STOVE

2.1 Locate the control valve on the appliance. There are two

control knobs on the valve, the right-hand knob controls the

pilot ignition and the left-hand knob controls the main

burner.

2.2 If your appliance has already been upgraded to battery

remote control, please refer to the instructions provided with

the upgrade to operate the remote control. The following

instructions will work for either situation.

2.3 Ensure that the left-hand control knob is pointing to off ( )
2.4 Ensure that the right-hand control knob is pointing to off ( ).
2.5 Press in the right-hand control knob and rotate it

anticlockwise until a click is heard (keep pressing in) and the

knob is pointing to pilot ( ). The pilot should now light. If

the pilot has not lit, repeat the procedure until it does.

2.6 Keep the control knob pressed in for 10 seconds and then

release it, the pilot should stay alight. If the pilot goes out,

repeat the procedure until does.

2.7 If the pilot will not light after repeated attempts, contact the

retailer or installer from whom the appliance was purchased.

2.8 Turn the right-hand control to point to main burner (

) .

The appliance can now be controlled using the left-hand

control knob.

2.9 Turn the left-hand control knob to point to low fire ( ) the

main burner will light on low. The burner can now be

controlled between low and high settings. Turn the control

knob anti-clockwise to increase the flame height and

clockwise to decrease the flame height.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE

HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20

MINUTES.

IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN

USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO

RELIGHT THE APPLIANCE.

1

AR0531a

AR0531b

2

AR0914

Advertising