SECTiON 2: CiRCUiT REQUiREMENTS

full Load amperage Draw

g0671 @ 220v ..................................... 32 amps
g0672 @ 220v ..................................... 34 amps
g0673 @ 220v ..................................... 30 amps
g0673 @ 440v ..................................... 15 amps

NOTICE

The Model G0671/G0672/G0673 is prewired

for 220V operation. if you plan to use your

Model G0673 at 440V, you MUST have a

qualified electrican perform the 440V con-

version described on this page.

Operation

Serious personal injury could occur if you

connect the machine to power before com-

pleting the setup process. DO NOT connect

the machine to the power until instructed

later in this manual.

Electrocution or fire could

result if machine is not

grounded and installed in

compliance with electrical

codes. Compliance MUST

be verified by a qualified

electrician!

figure 2. hardwired locking disconnect switch.

hardwired locking

disconnect switch

Power Connection Device

We recommend having an electrician hardwire
the machine (using a metal conduit setup) directly
to a locking disconnect switch (

figure 2), which is

directly connected to the power source.

g0671 Minimum Circuit size .................40 amps
g0672 Minimum Circuit size .................50 amps
g0673 Minimum Circuit size (220v) .....40 amps
g0673 Minimum Circuit size (440v) .....20 amps

the Model

g0673 can be converted for 440v

operation. this conversion job consists of discon-
necting the dust collector from the power source,
changing the magnetic switch, and rewiring the
motor for 440v operation, as shown on

Page 42.

the necessary magnetic switch for this procedure
can be purchased by calling grizzly Customer
service at (800) 523-4777 and ordering Model
g8296 (3-phase 440v 10hp Mag switch).

all wiring changes must be inspected by a quali-
fied electrician before the dust collector is con-
nected to the power source. if, at any time during
this procedure you need help, call grizzly tech
support at (570) 546-9663.

440V Conversion

Power Supply Circuit Requirements

the power supply circuit for your machine Must
be grounded and rated for the amperage given
below. never replace a circuit breaker on an exist-
ing circuit with one of higher amperage without
consulting a qualified electrician to ensure compli-
ance with wiring codes.

if you are unsure about

the wiring codes in your area or you plan to

connect your machine to a shared circuit, con-

sult a qualified electrician.