G0513 Series Bandsaws

Figure 5. typical 6-15 plug and receptacle.

Grounding Prong

Current Carrying Prongs

6-15 PLUG

GROUNDED

6-15 RECEPTACLE

Grounding Requirements

This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.

Grounding Requirements for 220V: the plug
specified under “Circuit requirements for 220V
operation” on this page has a grounding prong
that must be attached to the equipment-grounding
wire inside the specified power cord. the plug
must only be inserted into a matching recep-
tacle (see

Figure 5) that is properly installed and

grounded in accordance with all local codes and
ordinances.

Model Number

G0513, G0513P, G0513ANV, G0513X2,

G0513X2F

G0513X2B & G0513X2BF

circuit Requirements For 220V Operation:
Nominal Voltage

220V/240V

Cycle

60 hz

phase

single-phase

power supply Circuit

15 amps

plug/receptacle

NEMa 6-15

power Cord

“s”-type, 3-Wire, 14 aWg, 300 VaC

circuit Requirements For 110V Operation:
Nominal Voltage

110V/120V

N/a

Cycle

60 hz

phase

single-phase

power supply Circuit

30 amps

plug/receptacle

NEMa l5-30

power Cord

“s”-type, 3-Wire, 12 aWg, 300 VaC

circuit Requirements

these machines are prewired to operate on a 220V power supply circuit that has a verified ground and meet
the 220V operation requirements listed below.

Models g0513, g0513p, g0513aNV, g0513X2, and g0513X2F can be converted to operate on a 110V
power supply (refer to

Voltage conversion instructions beginning on Page 69) that has a verified ground

and meet the 220V operation requirements listed below.