Gateway 8450R User Manual

Page 54

Advertising
background image

Memory

53

When you select and install DIMMs, keep the following in mind:

Registered DIMMs should not be combined with unbuffered DIMMs.

Memory must be installed in complete banks (four DIMMs at a time),
from bank A to bank D.

No jumper settings are required for the memory size or type because the
BIOS automatically detects this information.

16 GB maximum system memory.

Memory banks are arranged as shown in the figure below.

To replace DIMMs:

1

Turn off the server and disconnect the power cord and all other external
peripheral devices.

2

Remove the back top panel. (See “Removing the back top panel” on
page 28 and “Preventing static electricity discharge” on page
25.)

C3

D3

C1

D1

C4

D4

C2

D2

A3

B3

A1

B1

A4

B4

A2

B2

8506284.book Page 53 Thursday, July 13, 2000 11:43 AM